Sign In | Join Free | My hardware-wholesale.com |
|
Brand Name : BOTO
Model Number : B-T-1000(A~E)
Certification : MIL STD GB JIS JEDEC IEC ISO
Place of Origin : China
MOQ : 1PCS
Price : Discussible
Payment Terms : L/C, T/T, Western Union
Supply Ability : 1000PC/Month
Delivery Time : 15days
Packaging Details : wooden case
Model : B-T-1000(A~E)
Internal : 60x75x50
External Dim : 90X177X130
heat-up time : ±1.0℃/±3.0℃RH
Temp&Humi.Deviation : -40℃-150℃
HighTemp Rang : +80℃~200℃
Interior : SUS#304Stainless steel plate
Exterior : Coating or SUS#304Stainless steel plate
Relative Humidity : 20%~98%RH
Power Source : AV:220V/380V 50/60Hz
Environmental Test Chambers GB/T2423.2 Programmable High Temperature Chamber
The constant temperature and humidity test chamber is composed of two parts: temperature regulation (heating, cooling) and humidification. Through the rotating fan installed in the top of the box, the air is discharged into the box to achieve gas circulation and balance the temperature and humidity inside the box. The data collected by the built-in temperature and humidity sensor of the box is transmitted to the temperature and humidity controller (micro information processor) for editing and processing, and the temperature and humidity control instructions are issued. Through the air heating unit, condensing pipe and the tank heating and evaporation unit.
Constant temperature and humidity box temperature regulation is through the box built-in temperature sensor, data collection, temperature controller (micro information processor) adjustment, connected to the air heating unit to increase the temperature or adjust the refrigeration solenoid valve to reduce the temperature in the box, in order to achieve the required temperature control. Constant temperature and humidity box humidity regulation is through the body set humidity sensor, data collection, humidity controller (micro information processor) adjustment, connected to the tank heating element, through the evaporation of water in the tank to increase the humidity in the box or adjust the refrigeration solenoid valve to achieve dehumidification, in order to control the required humidity.
Operation:
Through three interconnected systems: refrigerant circulation system, air circulation system, electrical automatic control system.
Refrigerant circulation system of constant temperature and humidity test chamber: The liquid refrigerant in the evaporator absorbs the heat of the air (the air is cooled and dehumidified) and begins to evaporate. Finally, a certain temperature difference is formed between the refrigerant and the air. The liquid refrigerant also completely evaporates into the gas phase, and is then inhaled and compressed by the compressor (pressure and temperature increase). After being throttled through the expansion valve (or capillary), low temperature and low pressure refrigerant enters the evaporator to complete the refrigerant circulation process.
| model | B-RUL-45 | B-RUL--60 | B-RUL-80 | B-RUL-100 | ||||||
design dimension | 45x45x45 | 60x60x60 | 80x80x80 | 100x100x100 | |||||||
carton size | 103x123x77 | 118x138x92 | 138x158x112 | 158x178x132 | |||||||
RT+10℃-200℃(1300°℃) | |||||||||||
economy | model
| DHG-9030A 101A-0S | DHG-9070A 101A-1S | DHG-9140A 101A-2S | DHG-9240A 101A-3S | DHG-9420A 101A-4S | DHG-9620A | ||||
volume | 30L | 70L | 136L | 220L | 420L | 620L | |||||
Interior dimension | 350*350*350 | 450*350*450 | 550*450*550 | 600*500*750 | 640*585*1355 | 840*600*1355 | |||||
mmW*D*H carton size | 480*470*685 | 580*470*785 | 680*590*885 | 730*640*1085 | 780*750*1880 | 980*800*1880 | |||||
temperature fluctuation | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | |||||
temperature resolution | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ | |||||
temperature control range | RT+10-250℃ | RT+10-250℃ | RT+10-250℃ | RT+10-250℃ | RT+10-200℃ | RT+10-200℃ | |||||
mains input | 220V 50HZ | 220V 50HZ | 220V 50HZ | 220V 50HZ | 220V 50HZ | 220V 50HZ | |||||
input powe | 650W | 1500W | 2000W | 2400W | 4000W | 4800W | |||||
volume | 30L | 70L | 136L | 220L | 420L | 620L |